AC Ripple and Power Factor

AC Ripple and Noise on the DC Outputs

 

The amount of AC ripple and noise present on the DC outputs was checked using an oscilloscope.  This AC component may be present in the KHz range where most switching power supplies operate or it may be more prevalent at the 60 Hz line frequency.  I adjusted the O-scope time base to look for AC ripple at both low and high frequencies. 

 

The new ATX12V V2.2 specification for DC output noise/ripple is defined in the ATX12V Power Supply Design Guide.

 

PC Power & Cooling Turbo-Cool 1200W PSU Review - Cases and Cooling 48 

 

Ideally we would like to see no AC ripple (repetitive) or noise (random) on the DC outputs; the cleaner the better!  But in reality there will always be some present.  I measured the amplitude of the AC signal (in millivolts, peak-to-peak) to see how well the power supply complied with the ATX standard.  The following table lists the ripple/noise results during all of the load tests for the four main output voltages of interest.

 

PC Power & Cooling Turbo-Cool 1200W PSU Review - Cases and Cooling 49 

 

The Turbo-Cool 1200W power supply exhibited excellent AC ripple suppression across the entire load range.  Even at max load with the +12V rail delivering 88A the +12V waveform barely broke 30mV.  PC Power & Cooling claims the Turbo-Cool 1200W PSU was designed to deliver super-clean DC outputs and they aren’t kidding!

 

Power Factor (PF)

 

Power factor (PF) is one of those mysterious properties of AC that even most electrical engineers have a hard time explaining.  I’m only presenting a brief overview of the subject; for a more detailed discussion about PF, please see my expanded comments in this review.

 

PC Power & Cooling Turbo-Cool 1200W PSU Review - Cases and Cooling 50 

 

AC Volts x AC Amps = VA (Volt Amp)

 

Purely Resistive AC Load: VA = Watts (same as DC circuits)

Inductive/Reactive AC Load: VA x PF = Watts 

 

AC Volts x AC Amps x PF = Watts 

 

Power factor is defined as the ratio of true power (measured in watts) to apparent power (measured in Volt Amps).  It measures how effectively AC power is being used by a device.  The difference between true power and apparent power is expressed as the power factor and results from the way true power and apparent power are measured.  Ideally we would like to have true power and apparent power equal to one another, which would result in a PF of 1.00 or 100% effective power utilization. 

 

I measured the AC Power Factor with an Extech power analyzer at both 115 VAC and 240 VAC input voltages.  The Turbo-Cool 1200W power supply uses Active PFC circuits so as expected; the majority of readings were close to 1.0. 

 

PC Power & Cooling Turbo-Cool 1200W PSU Review - Cases and Cooling 51 

 

Note: A power supply with active PFC is more environmentally friendly (doesn’t pollute the AC transmission grid with harmonics) and will draw less current, but it will not save you money on your monthly electric bill unless you are a commercial user whose bill is based on PF and usage. 