AC Ripple and Power Factor
AC Ripple and Noise on the DC Outputs

The amount of AC ripple and noise present on the DC outputs was checked using an oscilloscope.  This AC component may be present in the KHz range where most switching power supplies operate or it may be more prevalent at the 60 Hz line frequency.  I adjusted the O-scope time base to look for AC ripple at both low and high frequencies. 

The ATX12V V2.2 specification for DC output noise/ripple is defined in the ATX12V Power Supply Design Guide.

Seasonic X Series 400W Fanless Power Supply Review - Cases and Cooling 40

Ideally we would like to see no AC ripple (repetitive) or noise (random) on the DC outputs – the cleaner the better!  But in reality there will always be some present.  I measured the amplitude of the AC signal (in millivolts, peak-to-peak) to see how well the power supply complied with the ATX standard.  The following table lists the ripple/noise results during all of the load tests for the main output voltages of interest.

Seasonic X Series 400W Fanless Power Supply Review - Cases and Cooling 41

The Seasonic X Series 400W Fanless power supply exhibited very good AC ripple suppression on all of the primary outputs and stayed way below the recommended values, even at full load. One anomaly we noted was a sudden increase on the +5VSB rail when we went from 50W to 80W total load.  The AC ripple jumped from 3mV to 18mV with only a 0.5A increase.  Once the total load increased to 300W or 400W the AC ripple dropped back to 6mV.  This only occurred when going up in power and did not happen when decreasing from 300W to 200W or 200W to 80W.

Seasonic X Series 400W Fanless Power Supply Review - Cases and Cooling 42
(+5VSB/1A, 80W Total Load)


Seasonic X Series 400W Fanless Power Supply Review - Cases and Cooling 43
(+5VSB/2A, 400W Total Load)

Power Factor (PF)

Power factor is defined as the ratio of true power (measured in watts) to apparent power (measured in Volt Amps).  It measures how effectively AC power is being used by a device.  The difference between true power and apparent power is expressed as the power factor and results from the way true power and apparent power are measured.  Ideally we would like to have true power and apparent power equal to one another, which would result in a PF of 1.00 or 100% effective power utilization.

Seasonic X Series 400W Fanless Power Supply Review - Cases and Cooling 44

AC Volts x AC Amps = VA (Volt Amp)

Purely Resistive AC Load: VA = Watts (same as DC circuits)
Inductive/Reactive AC Load: VA x PF = Watts

AC Volts x AC Amps x PF = Watts

I measured the AC Power Factor with an Extech power analyzer at both 115 VAC and 240 VAC input voltages.  The X Series uses Active PFC circuits so as expected; the majority of readings were close to 1.00 at the higher loads. 

Seasonic X Series 400W Fanless Power Supply Review - Cases and Cooling 45

Note: PF and efficiency is not the same thing.  A power supply with active PFC is more environmentally friendly (doesn’t pollute the AC transmission grid with harmonics) and will draw less current, but it will not save you money on your monthly electric bill unless you are a commercial user whose bill is based on PF and usage. 


« PreviousNext »