Efficiency, Differential Temperature and Noise
Efficiency

The overall efficiency of a power supply is very important, especially when operating at higher power levels.  The less waste heat generated the better!  Efficiency is defined by the power output divided by the power input and is expressed as a percentage.  If a PSU were a 100% efficient (which none are) 900 watts of AC power going in would result in 900 watts of DC power coming out (with no waste heat to dissipate).  In the real world there are always inefficiencies and power is lost in the form of heat during the conversion process.

PC Power & Cooling Silencer Mk II 950W PSU Review - Cases and Cooling 35

The latest revisions to the ATX12V Power Supply Design Guide V 2.2 have continued to increase the efficiency recommendations for PC switching mode power supplies and now lists both required and recommended minimum efficiencies.

PC Power & Cooling Silencer Mk II 950W PSU Review - Cases and Cooling 36

I measured the AC power input to the Silencer Mk II 950W PSU with the Extech power analyzer while the total DC load was found by adding all the individual +3.3V, +5V, +12V, -12V and +5VSB loads together. 

PC Power & Cooling Silencer Mk II 950W PSU Review - Cases and Cooling 37


PC Power & Cooling Silencer Mk II 950W PSU Review - Cases and Cooling 38

The overall efficiency of the Silencer Mk II 950W power supply is very good and meets the requirements for 80 Plus Silver certification (it actually comes very close to meeting the requirements for Gold certification).  Note that efficiency will almost always be higher at the 240 VAC line voltage versus 115 VAC (as the voltage goes up the current goes down, and since line/component loses are proportional to current, less current means lower loses).

80 Plus Program

There is a growing awareness among users, PC manufacturers and electric utilities regarding the money and natural resources that could be saved by adopting higher efficiency PC power supplies.  One group that is spearheading this movement is the 80 Plus Program, which is supported by the electric utilities industry.  You can learn more about their efforts to promote power supplies with better than 80% efficiency by visiting the 80 Plus Program website.

PC Power & Cooling Silencer Mk II 950W PSU Review - Cases and Cooling 39

    Note 1: Power Factor =0.90 (50% to 100% Load)
    Note 2: Tests conducted at room temperature (25°C)

Spending a little more money up front to purchase a high efficiency power supply may very well pay for itself over the lifetime of the PC, especially when you are using this much power… 🙂

Differential Temperature and Noise Levels

To simulate real world operation the Silencer Mk II 950W power supply was mounted in a modified mid tower case (Lian Li PC60) for testing.  Some of the warm exhaust air from the PSU under test is recirculated back into the case, which allows the internal case air temperature to increase with load, just like it would in a real PC.  The internal case air temperature is allowed to increase up to 40ºC and then held constant from then on at 40ºC. 

The differential temperature across the Silencer Mk II 950W power supply was calculated by subtracting the internal case air temperature (T in) from the temperature of the warm exhaust air flowing out the back of the power supply (T out). 

Thermocouples were placed at the air inlet and exhaust outlet. The ambient room air temperature was 20ºC (68ºF) +/- 0.5ºC during testing.

T out = temperature of air exhausting from power supply
T in = temperature of air entering power supply
Delta T = T out – T in

Sound pressure level readings were taken 3’ away from the rear of the case in an otherwise quiet room.  The ambient noise level was ~28 dBA. 

PC Power & Cooling Silencer Mk II 950W PSU Review - Cases and Cooling 40

The 135mm cooling fan does a very good job of keeping the Mk II 950W PSU cool, even under heavy loads.  While not silent, even at the lower power levels, it is much quieter than any PC P&C Silencer model we have reviewed to date.

Note: I was not able to measure the SPL when the power supply was running at the higher loads because all the programmable DC load cooling fans were also running.